Stop module without damping ASU-800

For stopping and separating of one or more accumulated workpiece carriers a defined workpiece carrier stop surface.

Technical data

TYPE

Variants with 10 and 20 mm lowering stroke available.
Suitable for various systems and applications.

PRODUCT WEIGHT

ASU-800-…-10: 1,12 kg
ASU-800-…-10-E: 1,23 kg
ASU-800-…-10-I: 1,27 kg
ASU-800-…-20: 1,27 kg
ASU-800-…-20-E: 1,38 kg
ASU-800-…-20-I: 1,47 kg

PROPULSIVE FORCE

In order to ensure a perfect lowering movement of the stop module, the following propulsive forces must not be exceeded:
ASU-800-EW-10: FRmax = 675 N
ASU-800-DW-10: FRmax = 830 N
ASU-800-EW-20: FRmax = 580 N
ASU-800-DW-20: FRmax = 745 N

FUNCTION EW

EW (single-acting): The lowering of the stop module is done by pneumatic pressure.
In the unpressurized state, the stop module moves upwards into the blocking position by a spring and the next workpiece carriers can be stopped.
https://www.asutec.de/wp-content/uploads/2023/06/1-asu-ew.png

FUNCTION DW

DW (double-acting): The lowering and raising of the stop module is done by pneumatic pressure.
In unpressurized state the stop module keeps his last reached position. The stop module has no spring. This increases the lowering force.
https://www.asutec.de/wp-content/uploads/2023/06/2-asu-dw.png

INSTALLATION

The stop module is fastened using the side mounting holes for M8 screws.

TEMPERATURE RANGE

Standard version: -20°C to +80°C
-H = Heat resistant -20°C to +180°C
-E = Version with „-E’-query: +5°C to +60°C

PNEUMATIC CONNECTION

M5 on the back and front.

FURTHER TECHNICAL INFORMATION

See „Data sheet / operating manual’
in the ‘Downloads’ area

Variants

No items found

ASU-800-EW-10

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 10 mm lowering stroke

ASU-800-EW-20

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 20 mm lowering stroke

ASU-800-EW-20-I

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 20 mm lowering stroke
Option to query the upper and lowered position with inductive sensors

ASU-800-EW-20-I-G

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 20 mm lowering stroke
Option to query the upper and lowered position with inductive sensors
With tapped holes in the stop plate

ASU-800-EW-20-E

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 20 mm lowering stroke
Option to query the upper and lowered position with T-slot magnetic field sensors

ASU-800-EW-20-E-G

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 20 mm lowering stroke
Option to query the upper and lowered position with T-slot magnetic field sensors
With tapped holes in the stop plate

ASU-800-EW-20-G

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 20 mm lowering stroke
With tapped holes in the stop plate

ASU-800-DW-20

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 20 mm lowering stroke

ASU-800-DW-20-I

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 20 mm lowering stroke
Option to query the upper and lowered position with inductive sensors

ASU-800-DW-20-I-G

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 20 mm lowering stroke
Option to query the upper and lowered position with inductive sensors
With tapped holes in the stop plate

ASU-800-DW-20-E

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 20 mm lowering stroke
Option to query the upper and lowered position with T-slot magnetic field sensors

ASU-800-EW-10-100

Stop module without damping for workpiece carrier loads up to 450 kg
Reduced operating range (like ASU-400 wiht additional 50 kg)
Single acting function, 10 mm lowering stroke
Stop plate 21 mm wide, offset to the side, rotatable
Delivery including fastening set 75000010 and air connector 14010008

ASU-800-DW-20-E-G

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 20 mm lowering stroke
Option to query the upper and lowered position with T-slot magnetic field sensors
With tapped holes in the stop plate

ASU-800-DW-20-G

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 20 mm lowering stroke
With tapped holes in the stop plate

ASU-800-EW-10-H

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 10 mm lowering stroke
Heat resistant up to 180°C

ASU-800-EW-10-I

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 10 mm lowering stroke
Option to query the upper and lowered position with inductive sensors

ASU-800-EW-10-I-G

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 10 mm lowering stroke
Option to query the upper and lowered position with inductive sensors
With tapped holes in the stop plate

ASU-800-EW-10-I-100

Stop module without damping for workpiece carrier loads up to 450 kg
Reduced operating range (like ASU-400 wiht additional 50 kg)
Single acting function, 10 mm lowering stroke
Stop plate 21 mm wide, offset to the side, rotatable
Option to query the upper and lowered position with inductive sensors
Delivery including fastening set 75000010 and air connector 14010008

ASU-800-EW-10-E

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 10 mm lowering stroke
Option to query the upper and lowered position with T-slot magnetic field sensors

ASU-800-EW-10-E-100

Stop module without damping for workpiece carrier loads up to 450 kg
Reduced operating range (like ASU-400 wiht additional 50 kg)
Single acting function, 10 mm lowering stroke
Stop plate 21 mm wide, offset to the side, rotatable
Option to query the upper and lowered position with T-slot magnetic field sensors
Delivery including fastening set 75000010 and air connector 14010008

ASU-800-EW-10-G

Stop module without damping for workpiece carrier loads up to 800 kg
Single acting function, 10 mm lowering stroke
With tapped holes in the stop plate

ASU-800-DW-10

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 10 mm lowering stroke

ASU-800-DW-10-H

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 10 mm lowering stroke
Heat resistant up to 180°C

ASU-800-DW-10-I

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 10 mm lowering stroke
Option to query the upper and lowered position with inductive sensors

ASU-800-DW-10-I-G

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 10 mm lowering stroke
Option to query the upper and lowered position with inductive sensors
With tapped holes in the stop plate

ASU-800-DW-10-E-G

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 10 mm lowering stroke
Option to query the upper and lowered position with T-slot magnetic field sensors
With tapped holes in the stop plate

ASU-800-DW-10-G

Stop module without damping for workpiece carrier loads up to 800 kg
Double acting function, 10 mm lowering stroke
With tapped holes in the stop plate
Previous page Next page